Free ASC resource · Updated November 22, 2026

Cybersecurity Plan Readiness Checklist

USCG 33 CFR Part 101, Subpart F · updated for NVIC 02-26

For Facility Security Officers, Cybersecurity Officers and port, terminal and vessel operators preparing for the Coast Guard’s maritime cyber rule. Every item ties to its section of the rule, so you can see exactly what is required and where to find it.

Cybersecurity Plans are due to the Coast Guard by July 16, 2027.

Key dates

  1. July 16, 2025

    Rule in effect

    Reportable cyber incidents go to the National Response Center without delay.

    § 101.650(g)(1)

  2. January 12, 2026

    Training required

    All personnel with IT or OT access, and key personnel, trained; then annually. Still in effect before your Plan is filed. If yours is not done, close the gap now and document it.

    § 101.650(d)(4)

  3. July 16, 2027

    Assessment and Plan due

    Cybersecurity Assessment complete and Cybersecurity Plan submitted. From this date you operate under your submitted Plan.

    § 101.655

  4. After approval

    Ongoing cycle

    Plan-provisions training within 60 days; annual audit, Assessment, drills and exercise; penetration test before each 5-year renewal.

    § 101.630(f)(1)

How to use this checklist

Work through each area with your FSO, IT and OT leads. Check an item when it is in place and documented, since the Coast Guard will look for both. Each citation links to the rule text on eCFR. Section tags follow the Coast Guard’s preferred Plan layout (NVIC 02-26, Enclosure 1, Table 1). Gold-labeled notes summarize what NVIC 02-26 adds.

Build your Plan faster with ccSentinel

Much of this checklist comes down to evidence: asset inventories, vulnerability findings, KEV status and a written account of how you meet each requirement. ccSentinel, ASC’s Subpart F platform, automates that work so your team can build the Cybersecurity Plan in less time.

  1. Import

    Drag in SIW XML or Nessus, Rapid7, Action1, Yokogawa, Phosphorus or Companion data. Assets are assigned to each facility or vessel.

  2. Detect and map

    Findings are checked against the CISA KEV catalog (refreshed every 6 hours) and mapped to the Subpart F control areas.

  3. Report

    Generate print-ready reports with KEV matches, per-system detail, network topology maps and a compliance narrative to build your Plan from.

Free for organizations with up to 3 facilities and fewer than 200 endpoints. No credit card required.

Cybersecurity Officer and organization

Plan Section 1 Name who owns cybersecurity, early, and make sure the Coast Guard can reach them.

  • § 101.620(b)(3)

    NVIC 02-26Designate the CySO early so they can guide the Assessment and critical-system decisions. Enclosure (2) has an optional sample designation letter.

  • § 101.620(b)(3)

  • § 101.615

    NVIC 02-26Each alternate must meet the same qualifications as the primary CySO.

  • § 101.625(e)

    NVIC 02-26No specific certification or U.S. citizenship is required. Designating a CySO affirms to the Coast Guard that they qualify. The role can be filled in-house or by a contractor.

  • § 101.625(b)

  • § 101.620(b)(2)

    ASC tipInclude the FSO or VSO and your IT and OT engineers; the NVIC expects them to work with the CySO.

  • § 101.630(e)(4)

  • § 101.630(e)(3)

Cybersecurity Assessment

Plan Sections 11, 12 and 14 The Assessment sets the scope of the Plan. Do it first. It is due by July 16, 2027, then annually.

  • § 101.650(e)(1)

    NVIC 02-26The Coast Guard recommends completing the Assessment before drafting the Plan.

  • § 101.650(e)(1)(i)

    NVIC 02-26Enclosure (4) sorts assets into internal networks, external dependencies and interfaces.

  • § 101.650(e)(1)(i)

    NVIC 02-26A visual check or cursory review is not enough. Name the standard you used (for example, the NIST CSF) in the Assessment report.

  • § 101.615

    NVIC 02-26The NVIC’s “maybe” examples include tank level sensors, badge access servers and cargo release systems.

  • § 101.650(e)(1)(ii)

  • § 101.650(e)(1)(iii)

  • § 101.650(e)(1)(iv)

  • § 101.630(d)(2)

  • § 101.630(c)(14)

  • § 101.650(e)(1)

  • § 101.665

    NVIC 02-26A rigorous, standards-based Assessment is strongly recommended to support the request.

Writing and submitting the Plan

All sections Structure, protection and submission of the Cybersecurity Plan itself.

  • § 101.630(c)

    NVIC 02-26The Coast Guard prefers the Table 1 crosswalk. If you use it, say so on the first page. Keep the Cyber Incident Response Plan as an appendix.

  • § 101.630(a)

  • § 101.630(a)

    NVIC 02-26The Coast Guard recommends submitting the Plan as a discrete, cohesive package.

  • § 101.665

  • § 101.630(b)

  • § 101.630(a)

  • § 101.630(d)(2)

  • § 101.655

    NVIC 02-26Submissions use DoD SAFE under Coast Guard work instruction MCP-WI-003. For vessels, the NVIC routes Plans to the Office of Maritime Cybersecurity Policy (CG-MCP). The rule text still names the Marine Safety Center.

  • § 101.630(e)

  • § 101.630(d)(3)

  • § 101.630(e)(2)

  • § 101.660

Training and awareness

Plan Section 2 Training has been required since January 12, 2026. Confirm everyone is covered and that you can prove it.

  • § 101.650(d)(1)

    NVIC 02-26Physical access alone counts as access.

  • § 101.650(d)(4)

    NVIC 02-26Until July 16, 2027, follow CG-5PC Policy Letter 01-25.

  • § 101.650(d)(1)(v)

  • § 101.650(d)(2)

    NVIC 02-26Examples: leadership, CSO, FSO, VSO, admins, OT engineers with elevated access, and the CySO.

  • § 101.650(d)(4)

  • § 101.650(d)(4)

  • § 101.650(d)(3)

  • § 101.650(d)(1)

  • § 101.640

    NVIC 02-26If learning-system module titles don’t match the rule’s topics, keep a cross-reference.

Drills and exercises

Plan Section 3 Test the Plan and the people who run it.

  • § 101.635(b)(1)

    NVIC 02-26Space drills evenly through the year. They may be combined with existing MTSA drills.

  • § 101.635(c)(1)

  • § 101.635(c)(4)

  • § 101.635(c)(2)

  • § 101.635(c)(3)

  • § 101.635(c)(6)

  • § 101.635(a)(2)

Records and communications

Plan Sections 4 and 5 Keep the evidence, and make sure word gets out when conditions change.

  • § 101.640

    NVIC 02-26Also treat the approved list, inventory, network map and penetration test letter as records if kept outside the Plan.

  • § 101.630(b)

  • § 101.645(a)

  • § 101.645(b)

Systems, equipment and maintenance

Plan Section 6 Know what is on your network, control what gets installed, and keep it patched and backed up.

  • § 101.650(b)(1)

    NVIC 02-26Include enough detail to verify a model or version: name, version, manufacturer, approval and review dates, criticality.

  • § 101.650(b)(2)

  • § 101.650(b)(3)

  • § 101.650(b)(4)

  • § 101.650(e)(3)(i)

    NVIC 02-26“Without delay” means urgent action as soon as reasonably and safely possible. Use CISA’s KEV Catalog, and address KEVs on all systems too.

  • § 101.650(e)(3)(vi)

  • § 101.650(e)(3)(ii)

  • § 101.650(e)(3)(iii)

    NVIC 02-26The NVIC points to Area Maritime Security Committees, FBI InfraGard and CISA alerts. Sharing does not replace required reporting.

  • § 101.650(e)(3)(iv)

    NVIC 02-26Combine discovery scans, vulnerability scans and physical walk-downs.

  • § 101.650(e)(3)(v)

  • § 101.650(f)(1)

  • § 101.650(g)(4)

Access control, physical security and monitoring

Plan Sections 7, 8 and 9 Who can log in, who can touch the equipment, and how you would know.

  • § 101.650(a)(1)

  • § 101.650(a)(2)

  • § 101.650(a)(3)

  • § 101.650(a)(4)

  • § 101.650(a)(5)

  • § 101.650(a)(7)

    ASC tipTie this to HR offboarding and include contractor accounts.

  • § 101.650(h)(1)

  • § 101.650(h)(2)

  • § 101.650(c)(1)

  • § 101.650(c)(2)

  • § 101.650(i)(1)

  • § 101.650(i)(2)

  • § 101.650(f)(3)

Audits, amendments and vulnerability tracking

Plan Sections 10, 11 and 12 Prove the Plan works, track every finding and keep the Plan current.

  • § 101.630(f)(1)

  • § 101.630(f)(4)

  • § 101.630(f)(2)

  • § 101.630(f)(5)

  • § 101.630(c)(11)

    NVIC 02-26A living document, not on form CG-6025. Adding entries does not by itself require a Plan amendment.

  • § 101.630(c)(12)

  • § 101.650(e)(2)

    NVIC 02-26Not required for the initial July 2027 submission. Where live OT testing is unsafe, test the OT boundary.

  • § 101.625(d)(6)

Incident reporting and response

Plan Section 13 and CIRP appendix Know what to report, who reports it and how you recover.

  • § 101.615

    NVIC 02-26NVIC 02-24 (series) harmonizes the incident definitions in 33 CFR Parts 6 and 101.

  • § 101.650(g)(1)

  • § 101.620(b)(7)

    ASC tipTenants should coordinate reporting with the landlord port.

  • § 101.650(f)(2)

    ASC tipAdd this to contracts and renewal terms.

  • § 101.625(d)(10)

  • § 101.650(g)(2)

    NVIC 02-26Updating the Incident Response Plan does not require a Plan amendment, but include it in audits.

  • § 101.650(g)(3)

Stay current as guidance changes

Get a short email when the Coast Guard updates Subpart F guidance or this checklist changes. No spam; unsubscribe anytime.

Need help with your Assessment or Plan? Book a consultation with ASC.